Capnostream™ 20p bedside capnography monitor
The Capnostream™ 20p patient monitor with Microstream™ technology provides a complete measurement of a patient’s oxygenation and ventilation status.
Description
An accurate and continuous view of ventilation
The Capnostream™ 20p patient monitor is built on a legacy of proven performance. For nearly two decades, clinicians have relied on Microstream™ technology for an accurate, reliable view of ventilation adequacy on intubated and non-intubated patients, from neonate to adult.1
The Capnostream™ 20p monitor, with the apnea-sat alert feature, alerts caregivers to repetitive patterns of apneas and oxygen desaturation, revealing a more complete picture of a patient’s respiratory status.
Features
The dual parameter monitor supports current standards of care by providing etCO2 and SpO2 measurements.
The monitor is compatible with central monitoring systems and interfaces with nurse call systems and electronic medical records.
Smart Alarm Management™ integrated algorithms2,3 include Smart Alarm Management™ integrated algorithms, a suite of algorithms proven to reduce alarms and simplify the use of patient monitoring to enhance patient safety and improve clinical efficiency.4
Smart Breath Detection™ (SBD) screens out low amplitude "non-breath" etCO2 excursions like talking, crying, or snoring.
Smart Alarm for Respiratory Analysis™ (SARA) reduces 53% of clinically insignificant, unactionable nuisance alarms.5
Nellcor™ SatSeconds alerts clinicians to clinically significant changes in pulse oximetry.
Integrated Pulmonary Index™ algorithm (IPI) presents one value demonstrating real-time respiratory status based on etCO2, RR, PR, and SpO2.†
Apnea-Sat Alert™ algorithm (ASA)‡ tracks and reports apneas per hour and oxygen desaturation index and provides the data in trend reports.
Specifications
Power supply | |
|---|---|
Input voltage | 100-240VAC, 50/60Hz |
Fuses | Two F3.15A 250 volt |
Input power | 90 VA |
Battery | |
Battery type | 14.4V, 4.5Ah lithium-ion |
Battery operation | 2.5 hours (without thermal recorder) |
Battery charging time | 100% in 12 hours |
Controls | |
Front panel | 1 switch for monitor on/off control |
Display | |
Screen | 162 mm (6.4 in) color TFT display |
Trace speed | 3.0, 6.3, 12.5, and 25 mm/second |
Waveform sampling rate | 75.7 samples/second for SpO2 (fixed) |
Trend storage | 8640-point storage |
Trend display | Graphical display: 2-hour, 6-hour, 12-hour views |
Microstream™ capnography | |
CO2 units | mmHg or kPa or Vol% |
CO2, etCO2 FiCO2 range | 0–150 mmHg |
CO2, waveform resolution | 0.1 mmHg |
EtCO2, FiCO2 resolution | 1 mmHg |
CO2 accuracy | 0–38 mmHg: ±2 mmHg |
Respiration rate range | 0–150 bpm |
Respiration rate accuracy | 0–70 bpm: ±1 bpm |
CO2 alarms | No breath, etCO2 High, etCO2 Low, RR High, RR Low, Integrated Pulmonary Index™ algorithm (IPI). IPI also requires pulse oximetry information |
Flow rate | 50 (42.5 ≤ flow ≤ 65) mL/minute, flow measured by volume |
Waveform sampling | 20 samples/second |
Response time | 2.95 seconds (typical); with use with sampling lines with long tubing, ~5.0 seconds |
Initialization time | 40 seconds (typical) |
Calibration interval | Initially calibrate after 1,200 operating hours, then once a year or after 4,000 operating hours, whichever comes first |
Nellcor™ pulse oximetry | |
SpO2 measurement range | 1 to 100% |
SpO2 accuracy | |
Neonatal to adult | Saturation (% SpO2 ±1 SD) |
Low perfusion | 70 to 100% ±2 digits |
Alarms | Adjustable alarm limits |
Nellcor™ SatSeconds alarm management range | 10, 25, 50, 100 |
Data output and connectivity | |
Data output | USB storage to flash memory devices |
Connectivity options | Vital Sync™ virtual patient monitoring platform connectivity option |