Nellcor™ bedside SpO₂ patient monitor

The Nellcor™ bedside SpO₂ patient monitor offers a compact design, improved functionality, and an easy-to-read color user interface.

Description

Monitor with confidence

The Nellcor™ bedside respiratory patient monitor incorporates the latest Nellcor™ digital signal processing and cardiac-based technology for accurate, reliable readings. Because Nellcor™ pulse oximetry is closely tied to patient physiology, it provides consistent readings during various challenging conditions, such as patient movement, noise, and low perfusion which can impede the assessment of patient respiratory status. The patient monitoring system is also cleared as a motion-­tolerant bedside pulse oximeter that is compliant with ISO 80601-2-61.

With its intuitive, easy-to-read, graphical user interface and state-of-the-art color touch screen, this monitoring system provides clinicians with easy access to critical information they need for patient care. The system provides continuous SpO2, pulse rate, SatSeconds alarm management, and saturation pattern detection (SPD) alert, so clinicians may detect respiratory complications earlier and, therefore, intervene sooner.

Features

  • Multicolor display screen with a black background for contrast

  • Backup audible alarm

  • Multiple-language graphical user interface to support variety of users

  •  96-hour trend memory with data captured every four seconds

  • Distinctive digital signal processing technology

  • Simple, intuitive operation with a space-saving design

  • Displays plethysmographic waveforms, pulse amplitude, and current measured SpO2 and pulse rate

Technology

The Nellcor™ bedside SpO₂ patient monitoring system features a compact design, improved functionality, a built-in handle, and an intuitive, easy-to-read color user interface, making it simpler for clinicians to review and download critical patient data.

With its innovative features, advanced technology, and small footprint, this easy-to-use patient monitoring system helps clinicians save time and space.

  • A variable pitch beep tone enables clinicians to hear point-by-point changes in SpO2.

  • Patient trend data can be stored on a PC for archive and analysis.

  • An easy-to-use jog dial enables simple navigation and control of the display and monitoring system functions.

  • On-screen help messages assist with the use of the monitor.

  • Biomedical engineers and technicians can simply and effectively set institutional defaults as well as easily replace the battery, perform diagnostics to troubleshoot performance issues, and generally maintain the monitor within the hospital.

Specifications

Performance — measurement range

SpO2

1% to 100%

Pulse rate

20 to 250 beats per minute (bpm)

Pulse amplitude

0.03% to 20%

Accuracy

Saturation

(% SpO2 ± 1 SD)

Adult

70% to 100% ± 2 digits

Neonate

70% to 100% ± 3 digits

Low perfusion

70% to 100% ± 2 digits

Pulse rate

20 to 250 bpm ± 3 digits

Low perfusion

20 to 250 bpm ± 3 digits

Electrical — instrument

Power requirements

100 to 240 VAC, 50/60Hz, 45 VA

Fuse rating

Fast-acting 2A 32VAC/DC, fast-acting 500mA 32VAC/50DC

Electrical — battery

Type

Lithium ion

Battery capacity

Minimum of eight hours using new, fully charged battery with no alarms

Environmental — operating temperature

Instrument

5 C to 40 C (41 F to 104 F)

Transport/storage temperature (in shipping carton)

-20 C to 60 C (-4 F to 140 F)

Environmental — operating humidity

15% to 93% noncondensing

Environmental — operating altitude

-170 m to 4877 m (-557 ft to 16,000 ft)

Physical — weight

1.6 kg (3.5 lbs)

Physical — size

82 H x 255 W x 165 D (mm)

3.23 H x 10.04 W x 6.50 D (in)

Equipment compliance — standards

EN ISO 13485: 2016

EN ISO 14971: 2012

EN 980: 2008

EN 1041: 2008 + A1:2013

EN 60601-1: 2006 + A1:2013

EN 60601-1-2: 2015

EN 60601-1-6: 2010

EN 60601-8: 2007 + A1:2013

EN 62304: 2006

EN 62366: 2008

EN 14155: 2011

ISTA 2A: 2011

EN ISO 80601-2-61: 2011

EN 62133: 2017

Equipment classifications

Type of protection against electric shock

Class 1 (internally powered)

Degree of protection against electric shock

Type BF — applied part

Mode of operation

Continuous

Electromagnetic compatibility

EN 60601-1-2:2015

Liquid ingress

IPX2

Degree of safety

Not suitable for use in the presence of flammable anesthetics

Output

Trend data download

Nurse call capability

Display/indicators

Pulse

Amplitude indicator (eight segments)

Visual indicators

Pulse search, audible alarms silenced or off, interference indicator, battery charging, SatSeconds alarm management clock, pleth

Alarms

Audible and visual alarms for high/low saturation and pulse rate

SatSeconds alarm management settings: 10, 25, 50, and 100, or off

Audible and visual warning indicators for low battery and sensor off

Audible and visual sensor disconnect alarms

Ordering information

Item number

Description

Units per box

NELLSPO2

Monitoring system — includes 8 hour battery, interface cable and power cord

1

PT00155475

16 hour battery

1

PT00155120

8 hour battery

1

Hours